Search results for "Blood vessel prosthesis implantation"
showing 10 items of 106 documents
CT angiography for the assessment of EVAR complications : a pictorial review
2022
Aortic aneurysm; Blood vessel prosthesis implantation; Endovascular procedures Aneurisma aórtico; Implantación de prótesis de vasos sanguíneos; Procedimientos endovasculares Aneurisma aòrtic; Implantació de pròtesis de vasos sanguinis; Procediments endovasculars Endovascular aneurysm repair (EVAR) is a minimally invasive treatment proposed as an alternative to open repair in patients with abdominal aortic aneurysms. EVAR consists in a stent-graft placement within the aorta in order to exclude the aneurysm from arterial circulation and reduce the risk of rupture. Knowledge of the various types of devices is mandatory because some stents/grafts are more frequently associated with complication…
Evaluation of the stromal vascular fraction of adipose tissue as the basis for a stem cell-based tissue-engineered vascular graft
2017
Abstract Objective One of the rate-limiting barriers within the field of vascular tissue engineering is the lengthy fabrication time associated with expanding appropriate cell types in culture. One particularly attractive cell type for this purpose is the adipose-derived mesenchymal stem cell (AD-MSC), which is abundant and easily harvested from liposuction procedures. Even this cell type has its drawbacks, however, including the required culture period for expansion, which could pose risks of cellular transformation or contamination. Eliminating culture entirely would be ideal to avoid these concerns. In this study, we used the raw population of cells obtained after digestion of human lipo…
Biomechanical implications of excessive endograft protrusion into the aortic arch after thoracic endovascular repair
2015
Endografts placed in the aorta for thoracic endovascular aortic repair (TEVAR) may determine malappositioning to the lesser curvature of the aortic wall, thus resulting in a devastating complication known as endograft collapse. This premature device failure commonly occurs in young individuals after TEVAR for traumatic aortic injuries as a result of applications outside the physical conditions for which the endograft was designed. In this study, an experimentally-calibrated fluid-structure interaction (FSI) model was developed to assess the hemodynamic and stress/strain distributions acting on the excessive protrusion extension (PE) of endografts deployed in four young patients underwent TE…
Questionable Value of Adjuvant Arteriovenous Fistula in Pedal Bypass at High Risk for Early Failure
2007
Results of an adjuvant arteriovenous fistula (AVF) in pedal bypass surgery in the presence of poor status of the recipient artery, severely impaired intraoperative runoff, or revision for early failure and flow restitution were analyzed in a retrospective study. From January 1998 to December 2006, 24 adjuvant AVFs were constructed in autologous vein or composite pedal bypasses with low intraoperative bypass flow, poor status of the pedal artery, or during successful early bypass revision to prevent graft failure. All infrainguinal bypass operations were registered in a computerized database and prospectively followed. Pedal bypasses with adjunctive AVF were reviewed for fistula function, gr…
Symptomatic Deep Femoral Artery Pseudoaneurysm Endovascular Exclusion. Case Report and Literature Review.
2017
Deep femoral artery pseudoaneurysms (DFAPs) are rare and generally occur after penetrating trauma or surgical procedures. A 36-year-old obese man presented with pain in correspondence of the anterior-lateral thigh after 6 months from gunshot wound. Duplex and computed tomography (CT) showed a bilobed right DFAP (maximal diameter 12.9 cm). The patient was managed urgently, under local anesthesia, by placement in the distal DFA of a Viabahn 8 Ã 100-mm stent graft (W L Gore & Associates, Inc). The postoperative course was uneventful, and the 24-month CT showed regular stent-graft patency and 20-mm DFAP shrinkage. The literature review reported 8 cases of DFAPs; of these 6 were managed by endo…
Descriptive and follow-up study of patients treated surgically for abdominal aortic aneurysm at tertiary hospitals in Spain.
2019
BACKGROUND The aim of this study was to assess potential variability in the clinical characteristics and treatment of patients undergoing elective surgery for abdominal aortic aneurysm (AAA) across five hospitals in Spain. METHODS Multicenter, retrospective cohort study of patients diagnosed with AAA and treated with open surgical repair (OSR) or endovascular aneurysm repair (EVAR). We evaluated clinical and demographic variables, including comorbidity (Charlson Comorbidity Index [CCI]); anatomic characteristics; surgical risk (ASA Score); aneurysm characteristics; and in-hospital and overall mortality. All patients were followed for three years. RESULTS A total of 186 patients were include…
Multiple periscope and chimney grafts to treat ruptured thoracoabdominal and pararenal aortic aneurysms
2011
Purpose: To report midterm outcomes after urgent endovascular repair of ruptured pararenal or thoracoabdominal aortic aneurysms using multiple periscope and chimney grafts to preserve renovisceral branch perfusion and facilitate aneurysm exclusion. Methods: Nine consecutive men (mean age 72614 years, range 40–88) presenting with ruptured thoracoabdominal (n56), pararenal (n52), or infrarenal (n51) aortic aneurysm underwent urgent endovascular repair with at least 1 periscope graft delivered via a transfemoral access; chimney grafts were installed from an axillary access. In all, 17 periscope and 7 chimney grafts were used to reperfuse 11 renal and 13 visceral arteries in the 9 patients. The…
Endovascular treatment as first choice in chronic intestinal ischemia.
2002
The purpose of this study was to define the place of endovascular treatment in chronic intestinal ischemia (CII). We report here a series of 19 consecutive patients treated with percutaneous angioplasty of the intestinal arteries. We excluded patients with acute ischemia, from the study. From January 1, 1989 to December 31, 2001, 19 patients with symptomatic CII were treated by endovascular techniques. This study group included 11 men and 8 women with a mean age of 59 years (range 30 to 90 years). The clinical presentation included postprandial pain in 16 patients, weight loss in 14 patients, with a mean weight loss of 7.4 kg (range 0 to 30 kg); and gastroparesis in 2 patients. Stenoses wer…
The impact of Syme amputation in surgical treatment of patients with diabetic foot syndrome and Charcot-neuro-osteoarthropathy
2002
Charcot-neuro-osteoarthropathy with its severe destruction of bones remains a challenge for physicians and surgeons. The aim of the study was to characterise a patient population treated in a specialised foot care centre who underwent surgical treatment for their diabetic foot syndrome. Special attention was paid to patients who suffered from Charcot-neuro-osteoarthropathy and the impact of Syme amputation if amputation of the foot was inevitable. A total of 121 patients with diabetic foot syndrome and ulcerations underwent an interdisciplinary strategy for diagnostic and therapeutic procedures including MRI and surgical interventions. If peripheral arterial vessel disease was present, reva…
Chimney and periscope grafts to facilitate endovascular treatment of aortic transection in a patient with aberrant right subclavian artery
2014
Purpose: To report the use of parallel grafts to extend the proximal landing zone for stentgraft repair of aortic transection involving an aberrant right subclavian artery (ARSA). Case Report: A 28-year-old patient was referred for treatment of traumatic aortic transection with contained rupture at the level of an ARSA. Immediate thoracic endovascular aortic repair (TEVAR) was planned because of hemodynamic instability. To achieve rapid sealing and maintain perfusion to both subclavian arteries, a chimney stent to the left subclavian artery (LSA) and a periscope stent-graft to the ARSA were deployed successfully. After surgical repair of all fractures, the patient was discharged 1 month aft…